Tiêu chuẩn quốc tế

Số hiệu

Standard Number

AASHTO HB-17 DIVISION II SEC 4:2002
Năm ban hành 2002

Publication date

Tình trạng A - Còn hiệu lực

Status

Tên tiếng Anh

Title in English

Division II Construction - Driven Foundation Piles
Thay thế cho

Replace

AASHTO DIVISION II SEC 4:1996
Số trang

Page

9
Giá:

Price

Liên hệ / Contact us
Phạm vi áp dụng

Scope of standard

DESCRIPTION

This work shall consist of furnishing and driving foundation
piles of the type and dimensions designated on the plans or in the
special provisions including cutting off or building up foundation
piles when required. This specification also covers providing test
piles and performing loading tests. Piling shall conform to and be
installed in accordance with these specifications, and at the
location, and to the elevation, penetration, and bearing capacity
shown on the plans or as directed by the Engineer.

Any improperly driven, broken, or otherwise defective pile shall
be corrected to the satisfaction of the Engineer by removal and
replacement, or the driving of an additional pile, at no extra
cost.

Except when test piles are required, the Contractor shall
furnish the piles in accordance with the dimensions shown on the
plans or special provisions. When test piles are required, the pile
lengths shown on the plans are for estimating purposes only and the
actual lengths to be furnished for production piles will be
determined by the Engineer after the test piles have been driven.
The lengths given in the Engineer's order list will include only
the lengths anticipated for use in the completed structure. The
Contractor shall, without added compensation, increase the lengths
shown or ordered to provide for fresh heading and for such
additional length as may be necessary to suit the method of
operation.