Tiêu chuẩn quốc tế

Số hiệu

Standard Number

ASTM D5315-04(2017)e1
Năm ban hành 2017

Publication date

Tình trạng A - Còn hiệu lực

Status

Tên tiếng Anh

Title in English

Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization
Chỉ số phân loại Quốc tế (ICS)

By field

71.080 - Hóa chất hữu cơ
71.080.30 - Hợp chất nitơ hữu cơ
Số trang

Page

16
Giá:

Price

Liên hệ / Contact us
Phạm vi áp dụng

Scope of standard

1.1 This is a high-performance liquid chromatographic (HPLC) test method applicable to the determination of certain n-methylcarbamoyloximes and n-methylcarbamates in ground water and finished drinking water (1).2 This test method is applicable to any carbamate analyte that can be hydrolyzed to a primary amine. The following compounds have been validated using this test method: Analyte Chemical Abstract Services Registry Number A    Aldicarb       116-06-3    Aldicarb sulfone       1646-88-4    Aldicarb sulfoxide       1646-87-3    Baygon       114-26-1    Carbaryl       63-25-2    Carbofuran       1563-66-2    3-Hydroxycarbofuran       16655-82-6    Methiocarb       2032-65-7    Methomyl       16752-77-5    Oxamyl       23135-22-0 (A) Numbering system of Chemical Abstracts, Inc. 1.2 This test method has been validated in a collaborative round-robin study (2) and estimated detection limits (EDLs) have been determined for the analytes listed in 1.1 (Table 1). Observed detection limits may vary between ground waters, depending on the nature of interferences in the sample matrix and the specific instrumentation used. (A) Primary column-250 by 4.6 mm inside diameter Altex Ultrasphere ODS, 5 μm.(B) Confirmation column-250 by 4.6 mm inside diameter Supelco LC-1, 5 μm.(C) Estimated method detection limit in micrograms per litre. 1.3 This test method is restricted to use by, or under the supervision of, analysts experienced in both the use of liquid chromatography and the interpretation of liquid chromatograms. Each analyst should demonstrate an ability to generate acceptable results with this test method using the procedure described in 12.3. 1.4 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications should be confirmed by at least one additional qualitative technique. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Additional guidance on laboratory safety is available and suitable references for the information are provided (3-5). 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.