Tiêu chuẩn quốc tế
Số hiệu
Standard Number
ASTM D7303-17
Năm ban hành 2017
Publication date
Tình trạng
A - Còn hiệu lực
Status |
Tên tiếng Anh
Title in English Standard Test Method for Determination of Metals in Lubricating Greases by Inductively Coupled Plasma Atomic Emission Spectrometry
|
Chỉ số phân loại Quốc tế (ICS)
By field
75.100 - Chất bôi trơn, dầu công nghiệp và các sản phẩm liên quan
|
Số trang
Page 7
Giá:
Price Liên hệ / Contact us
|
Phạm vi áp dụng
Scope of standard 1.1 This test method covers the determination of a number of metals such as aluminum, antimony, barium, calcium, iron, lithium, magnesium, molybdenum, phosphorus, silicon, sodium, sulfur, and zinc in unused lubricating greases by inductively coupled plasma atomic emission spectrometry (ICP-AES) technique. 1.1.1 The range of applicability for this test method, based on the interlaboratory study conducted in 2005,2 is aluminum (10 to 600), antimony (10 to 2300), barium (50 to 800), calcium (20 to 50 000), iron (10 to 360), lithium (300 to 3200), magnesium (30 to 10 000), molybdenum (50 to 22 000), phosphorus (50 to 2000), silicon (10 to 15 000), sodium (30 to 1500), sulfur (1600 to 28 000), and zinc (300 to 2200), all in mg/kg. Lower levels of elements may be determined by using larger sample weights, and higher levels of elements may be determined by using smaller amounts of sample or by using a larger dilution factor after sample dissolution. However, the test precision in such cases has not been determined, and may be different than the ones given in Table 1. Note 1: X is the mean concentration in mg/kg. Element Range, mg/kg Repeatability Reproducibility Aluminum 10-600 0.2163 X0.9 6.8156 X0.9 Antimony 10-2300 0.3051 X0.8191 4.6809 X0.8191 Barium 50-800 0.3165 X0.7528 2.9503 X0.7528 Calcium 20-50 000 2.2853 X0.7067 3.0571 X0.7067 Iron 10-360 0.8808 X0.7475 2.5737 X0.7475 Lithium 300-3200 0.0720 X1.0352 0.1476 X1.0352 Magnesium 30-10 000 0.6620 X0.6813 2.6155 X0.6813 Molybdenum 50-22 000 0.1731 X0.9474 0.4717 X0.9474 Phosphorus 50-2000 1.2465 X0.6740 4.0758 X0.6740 Silicon 10-15 000 1.3859 X0.9935 4.8099 X0.9935 Sodium 30-1500 6.5760 X0.5 11.571 X0.5 Sulfur 1600-28 000 1.0507 X0.8588 1.5743 X0.8588 Zinc 300-2200 0.1904 X0.8607 0.5912 X0.8607 1.1.2 It may also be possible to determine additional metals such as bismuth, boron, cadmium, chromium, copper, lead, manganese, potassium, titanium, etc. by this technique. However, not enough data is available to specify the precision for these latter determinations. These metals may originate into greases through contamination or as additive elements. 1.1.3 During sample preparation, the grease samples are decomposed with a variety of acid mixture(s). It is beyond the scope of this test method to specify appropriate acid mixtures for all possible combination of metals present in the sample. But if the ash dissolution results in any visible insoluble material, the test method may not be applicable for the type of grease being analyzed, assuming the insoluble material contains some of the analytes of interest.
|