                                Title in English Standard Practice for Setting the Requirements for the Serviceability of a Building  or Building-Related Facility, and for Determining What Serviceability  is Provided or Proposed 
                             | 
                        
| 
                                 
                                    Chỉ số phân loại Quốc tế (ICS)
                                     
                                
                            By field  | 
                        
| 
                                                                     
                                        Số trang
                                         
                                    Page 17 
                                                                
                                    Giá:
                                     
                                Price Liên hệ / Contact us 
                             | 
                        
| 
                                 
                                    Phạm vi áp dụng
                                     
                                Scope of standard 1.1 This practice provides a definitive procedure for setting the level of requirements of the users (functionality) for the functional capability of a building or building-related facility.  1.2 This practice provides a definitive procedure for rating the level of functional capability (serviceability) provided by an existing building or building-related facility, or to be provided according to the design for one.  1.3 This practice provides a definitive procedure for creating or adapting a set of classifications for establishing the levels of functionality required of or the level of capability provided by a building or building-related facility.  1.4 This practice can be used for setting the profile of requirements of an occupant group in an existing building or building-related facility, or of a group planning to move and looking at new accommodations to rent, buy, or build, and it can be used to assess the suitability of their present facilities.  1.5 This practice can be used for setting the profile of requirements of an owner, facility manager, lender, or other investor.  1.6 This practice does not specify what would cause a building to be rated at a given level. That information is found in classifications for specific topics of serviceability that contain a set of rating scales.  1.7 This practice is not intended to be used for regulatory purposes.  1.8 This practice contains the following information, in the sections indicated:     Section   Introduction  1  Scope  1  Referenced Documents  2  Terminology  3  Significance and Use  4  Essence of the Approach  5  Procedure for Setting the Profile of Required Functionality  6  Procedure for Setting the Profile of Functional Capability for a Building or for Building-Related Facilities  7  Rating the Plans or Proposals for a New Building or for a Remodel or Rehabilitation Project  8  Keywords  9  Rules for Setting Levels in a Scale  Annex A1  Examples of Scales  Appendix X1 Steps for Setting the Functional Requirement Profile  Appendix X2 Steps for Setting the Facility Rating Profile  Appendix X3 Examples of Bar-Chart Profiles  Appendix X4 Example of Titles of Aspects, Topics and Features  Appendix X5 List of Common Types of Function  Appendix X6  1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. 
                             |